Fridge compressor replacement is the right repair when the compressor itself, the black unit low down at the back that many people call the motor, has failed. Plenty of fridges with an apparently dead motor have a failed start relay, overload protector or thermostat, which costs far less, so we test before we quote.
What the compressor does
The compressor is a pump and an electric motor sealed together inside a steel shell. It draws refrigerant gas out of the cooling pipes inside the fridge, squeezes it and pushes it, hot, into the condenser (the pipes at the back or inside the side walls), where the heat leaves the fridge. When it stops, the inside slowly warms up even though the light still works. This is the part people mean when they ask for a fridge motor replacement.
Signs of a fridge compressor not working, and what else to rule out
| What you notice | Cheaper causes to rule out first | It is the compressor when |
|---|---|---|
| Light on, compressor silent | Thermostat, control board, defrost timer, relay or overload | A winding reads open |
| Clicks every few minutes, stays warm | Start relay, overload protector, capacitor, low voltage | All of those test fine and it still will not start |
| Trips the earth leakage as it starts | Damp or damaged wiring, plugs or connectors | A winding leaks to the shell |
| Runs non-stop but stays warm | Gas leak, dirty condenser, failed fan | The pressures show it has stopped pumping |
The start relay gives the motor a boost to get going, and the overload protector cuts the power when the motor draws too much current or overheats, which is the click you hear. Some compressors also have a capacitor, which stores a charge to help the motor start or run. An inverter fridge usually has none of these, because its board starts the compressor.
A worn thermostat or sensor that never calls for cooling, or a faulty control board on an electronic fridge, leaves a healthy compressor sitting idle. Our guides to a fridge making noise and a fridge tripping the electricity explain those symptoms.
Before you book
Work through the safe checks in our guide to a fridge not cooling, from the setting to the condenser coils. If the fridge travelled on its side, let it stand upright and switched off for no less time than it spent lying down, preferably overnight, before you judge it. If it clicks every few minutes, unplug it so that repeated failed starts do not overheat the motor.
If the pipes were damaged or you hear hissing, remember that most fridges sold here use flammable R600a. Keep flames and sparks away and air the room for a few minutes before you switch off, unplug and phone us.
How we test the compressor
On a standard compressor, we measure the resistance between the three pins, where each pair has its own expected reading, so a winding that is open or shorted stands out. We check that no winding leaks to the shell, test the relay and overload, check the supply voltage while the compressor tries to start and measure the current it draws. If it runs, gauges separate a worn compressor from a gas leak: a leak pulls both pressures down, while a worn compressor leaves them too close together because it can no longer pump.
How a proper fridge compressor replacement is done
- The right compressor. It must suit the refrigerant on the rating plate, because R600a and R134a compressors are not interchangeable, and match the fridge’s cooling capacity and our 230 V, 50 Hz supply. An inverter fridge needs the matching inverter compressor.
- Safe gas removal. Our technicians, registered with SAQCC Gas, remove the old charge with the room aired and no flames nearby, then purge the system with nitrogen before any brazing.
- A new filter drier. It traps moisture and debris, so an old one is never reused.
- Brazed joints. The new compressor and filter drier are brazed into the pipework.
- Nitrogen pressure test. Dry nitrogen proves that every joint holds.
- Deep vacuum. Air and moisture are pumped out, which protects the new motor.
- Recharge by weight. We weigh in the exact refrigerant and amount on the rating plate.
- Temperature test. Before we leave, we check that it starts, draws the right current and pulls the temperatures down.
These are the same standards as a proper fridge regas. Keep the doors closed afterwards: the fridge takes a few hours to reach 3 to 5°C, and the freezer can take most of a day to reach -18°C.
Replace the compressor or the whole fridge?
Our rule of thumb: replacing the fridge starts to make sense once it is past about 10 to 12 years and the compressor has failed, or when the quote comes to more than half the price of a comparable new one. Then look at the rest of the fridge. A rusting cabinet, cracked liners, tired seals or an ageing control board can each turn one repair into several, and an old fridge with poor insulation keeps using more electricity even with a new compressor. Our Randburg repair-or-replace guide goes through each factor.
If your fridge is fairly new, check the warranty paperwork first, because many manufacturers cover the compressor, especially an inverter one, for longer than the rest of the fridge. We give you the full price before any work starts. We repair all major fridge brands. Book a compressor diagnosis online.