We do commercial fridge repairs on site across Gauteng, from Johannesburg to Pretoria, for shops, restaurants, bars and takeaways. We work on plug-in units with their own compressor: glass-door display fridges, bottle and beverage coolers, under-counter and double-door kitchen fridges, back-bar coolers and other plug-in commercial fridges. For a shop’s chest or upright freezer, see chest and upright freezer repairs.
Why commercial fridges fail differently
- Constant use. Doors open all day, so the unit runs longer and its seals, hinges and fans wear faster.
- Grease and dust. Kitchen grease and shop dust clog the condenser, the coil that sheds heat, so the compressor works harder.
- Hot rooms and blocked vents. Kitchen storage fridges often list a climate class in the manual: class 3 suits rooms up to 25°C, class 4 up to 30°C and class 5 up to 40°C. A container shop or a spot beside the fryer can get hotter than the class allows, and boxes against the grille trap heat.
- Packed shelves. Stock pressed against the fan or air outlets blocks the cold air, so parts of the cabinet run warm.
Display fridge and bottle cooler faults by symptom
| What you notice | Check first | What we test |
|---|---|---|
| Running, but stock is warm | Set point, doors, seals, condenser | Fans, an iced coil, a gas leak, the compressor |
| Ice on the coil or fan cover | A door left ajar, a torn seal | The defrost and its probe, a stopped fan, low gas |
| An alarm or code on the display | Photograph it | The probe, door switch or controller |
| Water on the floor | Level cabinet, clear drain hole | A blocked or split drain tube, a cracked tray |
| A door that will not close | Stock in the way, a forward lean | A worn hinge or closer, a folded seal |
| A new noise | Anything touching the fan or wall | Fan bearings, the start relay, a loose pipe |
Our guides to a fridge not cooling, a fridge leaking water and a noisy fridge go deeper, and we test fully before any compressor replacement. A code names the part that raised the alarm, not always the cause, so we test the wiring and readings before we replace a sensor or controller.
What your staff can check safely
If the plug or plug point is wet, scorched or sparking, switch off its circuit at the DB board before touching anything.
- A trip. If the earth leakage or a breaker trips, unplug the fridge and reset once. If it holds, leave it unplugged and book. If it still trips once the fridge is unplugged, call an electrician. Never move it to another plug point or circuit.
- Doors and load. Check each door closes on a whole seal, as our door seal replacement page explains, and keep stock below any load line.
- The condenser. Unplug the fridge, then brush along the fins with a soft brush and vacuum the dust. Never use water or a stiff or wire brush. Check it every three months, more often near grease or dust.
- After a power cut. Give it a few minutes: some controllers delay the restart.
- Ice. Switch off and let it melt on its own with towels down. No chipping with knives or scrapers, and no hair dryers, heat guns or hot water.
Keeping stock safe while the fridge is down
Keep the doors shut, with a note telling staff why. Left closed, a fridge keeps its contents cold for about 4 hours.
- Log it. Write down the time and the thermometer reading at each check, so you know how long stock has been warm.
- Move high-risk food first. Raw fish, shellfish, poultry, offal and milk, then other perishables, go into another fridge or cooler boxes with ice packs.
- Then sort the rest. Perishables that sat above 4°C for over two hours go in the bin. Our Heidelberg food safety guide lists the more forgiving foods. If in doubt, throw it out.
Commercial fridge regassing and R290 safety
The rating plate names the gas. Many newer plug-in units use R290 (propane), some R600a (isobutane), and older ones may use R134a. R290 and R600a are both flammable. If a pipe is damaged or hissing, keep every flame and spark well clear and open doors and windows for a few minutes. Then switch the unit off, unplug it and call us.
A proper commercial fridge regas means the leak is found and fixed, a new filter drier fitted, the system pressure tested with nitrogen, a deep vacuum pulled and the refrigerant on the rating plate weighed back in. We never just top up. Our technicians are registered with SAQCC Gas.
How a commercial fridge repair works
We are open 24/7, and day or night a technician is usually on site in about an hour. WhatsApp photos of the rating plate and display to 079 895 0496 when you book.
We find the fault first and give you a clear price before any work starts. You pay the R300 call-out fee only if you turn down the quoted repair. Every repair comes with a 6-month warranty.
Repair or replace?
Replacing starts to make sense once a unit is past about 10 to 12 years and its compressor has failed, or when the quote is over about half the price of a comparable new one. We repair all major fridge brands. Book a commercial fridge repair.